YD260 2-1/2'' Compressed Air Filter 14 m3/min for Refrigerated Air Dryer

Brand: YUKA
Product Type: Air Filtration
Product Series: YD Series
Model No.: YD260
Flow rate: 14.0 m³/min
Port Size: 2-1/2" RC/NPT/BSPT
Micron rating: 5 to 0.01 micron
Materials of Construction: Die Cast Aluminum
Operating pressure: 1.5 to 16 bar (22 to 232 psig)
Operating Temperature: 2 to 80 ℃
Housing Service Life: 15 years
Element Change Interval: 6000 to 8000 hours
Compatible Element: L260 PF/AO/AA/AX/ACS/AR/AAR
Accessories: DPG, SG, External Auto Drain, Manual drain valve
Origin: Shenzhen, China

EMAIL

YD260 Rc2-1/2'' High Efficiency Compressed Air Filter 14 m3/min for Refrigerated Air Dryer 


YUKA YD260 2-1/2 inch compressed air filters manufactured in an ISO 9001 approved facility and tested in accordance with ISO 12500-4.  Designed with filtration grades PF/AO/AA/AX/ACS/AR/AAR to exceed the ISO 8753-1 standards for compressed air purity & the ISO 12500 series international standard for compressed air filter testing. Our air filter housings are also subject to a 1000 hour neutral salt spray test for corrosion resistance to ISO 9227:2006, burst pressure test for a 5:1 safety factor, 100% tested for pressure leaks, and 100% tested for aerosol integrity.



YD260 Air Filter Function


- Remove dust, aerosols and oil vapors out of compressed air.

- Protect downstream equipment against the pollutants.

- Supply dry, clean compressed air to directly contact with end-point products.

- Reducing the energy consumption, total cost of ownership and adding to your satisfaction.



YD260 Air Filter Features


- YD260 air filter housings and elements designed to suit almost industrial applications.

- Filtration grade PF effectively removes particles down to 5 micron.

- YD260 2-1/2" inch air filter housings manufactured from aluminum alloys.

- Electrophoretically treated to extend the air filter housing life by up to fifteen years.

- A 1000 hours neutral salt spray test for corrosion resistance to ISO 9227:2006, burst pressure test for a 5:1 safety factor.

- Equipped with a differential pressure gauge, a sight glass and an internal auto drain and manual drain valve.

- Complies with ISO8573-1 air quality requirements. 



YD260 Compressed Air Filters Applications


- Paint spraying.

- Color sorter for agriculture.

- Sandblasting machines.

- Nitrogen and oxygen generation station.

- Chemical manufacturing.

- Pharmaceutical air/gas filtration and product transfer.

- Laser metal cutting.

- Food and beverages.

- Filtration of air in aseptic packaging.

- Filtration of compressed air of other inert gases.

- Manufacture of plastics (PET).



Product Selection


Below flow rates of compressed air are calculated in rated working pressure of 7 bar (100 psi g) with reference  to 20 ℃.

1709117616381062.png



Correction Factor


To correctly select an air filter model, the flow rate of the air filter must be adjusted for the minimum operating (inlet) pressure at the point of installation. 

Calculate the adjust  filtration capacity:

1.Minimum Filtration Capacity = Compressed Air Flow Rate x pressure correction factor rate.

2.Using the minimum filtration capacity, select an air filter model from the flow rate tables above (air filter selected must have a flow rate equal to or greater than the minimum filtration capacity).