YUKA DT013 Industrial Compressed Air Filters,0.01 Micron

Brand: YUKA
Product Type: Air Filtration
Product Series: DT Series
Model No.: DT013
Flow rate: 1.8 m³/min
Port Size: 1/2" RC/NPT/BSPT
Micron rating: 5 to 0.01 Micron
Materials of Construction: Die Cast Aluminum
Operating pressure: 1.5 to 16 bar (22 to 232 psig)
Operating Temperature: 2 to 80 ℃
Housing Service Life: 15 years
Element Change Interval: 6000 to 8000 hours
Compatible Element: DT013 PF/AO/AA/AX/ACS/AR/AAR
Accessories: DPI,SG, Internal drain
Origin: Shenzhen, China

EMAIL

YUKA DT013 1/2" Industrial Compressed Air Filters, 0.01 Micron


Brand: YUKA

Product Type: Air Filtration

Product Series: DT Series

Model No.: DT013

Flow rate: 1.8 m³/min

Port Size: 1/2" RC/NPT/BSPT

Micron rating: 5 to 0.01 Micron

Materials of Construction: Die Cast Aluminum

Operating pressure: 1.5 to 16 bar (22 to 232 psig)

Operating Temperature: 2 to 80 ℃

Housing Service Life: 15 years

Element Change Interval: 6000 to 8000 hours

Compatible Element: DT013 PF/A0/AA/AX/ACS/AR/AAR

Accessories: Differential pressure indicator, internal auto drain, sight glass

Origin: Shenzhen, China



DT013 Air Filter Features:

- Small air port design.

- Compact, modular design for quick and easy installation.

- Seven filtration grades available, particle removal down to 0.01 micron.

- Maximum remaining oil aerosol down to 0.001 mg/m3 at 20°C.

- Reliable and efficient removal of liquid and solid contaminants.

- Advanced airflow design for optimum performance and reduced pressure drops.

- External powder coated surface for enhanced abrasion and corrosion resistance.

- A safety and leakage test was conducted on each air filter.

- Automatic drain with manual override for testing and depressurization.

- Suited with a differential pressure indicator or gauge, sight glass and floating ball auto drain to facilitate efficient condensate draining. 


Product Selection

Below flow rates of compressed air are calculated in rated working pressure of 7 bar (100 psi g) with reference  to 20 ℃.

1709538530560032.png


Correction Factor

To correctly select an air filter model, the flow rate of the air filter must be adjusted for the minimum operating (inlet) pressure at the point of installation. 

Calculate the adjust  filtration capacity:

1.Minimum Filtration Capacity = Compressed Air Flow Rate x pressure correction factor rate.

2.Using the minimum filtration capacity, select an air filter model from the flow rate tables above (air filter selected must have a flow rate equal to or greater than the minimum filtration capacity).

1709117563406259.png