Brand: YUKA
Product Type: Air Filtration
Product Series: DT Series
Model No.: DT011
Flow rate: 1.2 m³/min
Port Size: 1/2" RC/NPT/BSPT
Micron rating: 5 to 0.01 Micron
Materials of Construction: Die Cast Aluminum
Operating pressure: 1.5 to 16 bar (22 to 232 psig)
Operating Temperature: 2 to 80 ℃
Housing Service Life: 15 years
Element Change Interval: 6000 to 8000 hours
Compatible Element: DT011
Accessories: DPI,SG, Internal drain
Origin: Shenzhen, China
DT011 1/2" Pneumatic Air Filters for Compressed Air Systems, Automatic Drain, Sight Glass
- Brand: YUKA
- Product Type: Air Filtration
- Product Series: DT Series
- Model No.: DT011
- Flow rate: 1.2 m³/min
- Port Size: 1/2" RC/NPT/BSPT
- Micron rating: 5 to 0.01 Micron
- Materials of Construction: Die Cast Aluminum
- Operating pressure: 1.5 to 16 bar (22 to 232 psig)
- Operating Temperature: 2 to 80 ℃
- Housing Service Life: 15 years
- Element Change Interval: 6000 to 8000 hours
- Compatible Element: DT011 PF/A0/AA/AX/ACS/AR/AAR
- Accessories: Differential pressure indicator, internal auto drain, sight glass
- Origin: Shenzhen, China
DT011 1/2" Pneumatic Air Filter Features:
- Small air port design.
- Compact, modular design for quick and easy installation.
- Seven filtration grades available, particle removal down to 0.01 micron.
- Maximum remaining oil aerosol down to 0.001 mg/m3 at 20°C.
- Reliable and efficient removal of liquid and solid contaminants.
- Advanced airflow design for optimum performance and reduced pressure drops.
- External powder coated surface for enhanced abrasion and corrosion resistance.
- A safety and leakage test was conducted on each air filter.
- Automatic drain with manual override for testing and depressurization.
- Suited with a differential pressure indicator or gauge, sight glass and floating ball auto drain to facilitate efficient condensate draining.
Product Selection
Below flow rates of compressed air are calculated in rated working pressure of 7 bar (100 psi g) with reference to 20 ℃.
Correction Factor
To correctly select an air filter model, the flow rate of the air filter must be adjusted for the minimum operating (inlet) pressure at the point of installation.
Calculate the adjust filtration capacity:
1.Minimum Filtration Capacity = Compressed Air Flow Rate x pressure correction factor rate.
2.Using the minimum filtration capacity, select an air filter model from the flow rate tables above (air filter selected must have a flow rate equal to or greater than the minimum filtration capacity).
Contact HSAIR Today
Do you have a question about compressed air dryers, particulate and coalescing air filters, water separators, automatic drains, service or our website? Please drop us an e-mail at sales@hsfiltration.com, HSAIR representative will be in touch with you shortly.
Contact: HSAIR Filtration
Phone: +86-186 2038 0784
E-mail: sales@hsfiltration.com
Whatsapp:+86-186 2038 0784
Add: Building T, Hengyu Industrial Park, Ruiji 1st Rd, 518116 Shen Zhen, Guang Dong, China
We chat